Railscan 125 Falcon

Sonatest-Railscan-125-Falcon

RS 125 Falcon -
Using the latest developments in amplifier and pulser technology to deliver higher levels of near surface resolution and penetrating power the Railscan 125 Ultrasonic Flaw Detector has been developed and designed specifically for Rail Testing within the Rail Infrastructure NDT market.
Designed specifically for Rail Testing, the Railscan 125R rises to the demanding challenges set by this environment for NDT and it’s operators.

Network Rail (UK) procedure and approval

Narrow Band amplifiers 2 and 5 MHz; G1 +ve trigger, G2 -ve trigger, (0.6 second delay for monitoring rail bottom depth).

Long Battery Life: Latest Li-Ion technology 10-16 hours (brightness dependant) Quick re-charge in 3-4 hours

Walking Stick Compatibility: Sperry walking stick. Others (e.g., NRS bi-directional walking stick)

Single-shot PRF for high speed multiplexing

RS232 & USB outputs: Supporting custom software systems, (e.g. Sperry palmtop with GPS

 

RS 125 Falcon Specification

Test Range:0 - 5mm (0.2in) up to 0 - 10000 mm (400 in.) at steel velocity. Variable in 1mm & 10mm steps.
Velocity:1000 to 9,999m/s continuously variable.
Probe Zero:0 to 999.999 μs, continuously variable.
Delay:Calibrated delay from 0-10000mm in 0.05 mm steps at steel velocity (0-400in. in 0.002 in. steps).
Gain:0 to 110dB. Adjustable in 0.5, 1, 2, 6, 10, 14 and 20dB steps. Direct access to gain control at all times.
Test Modes:Pulse echo and transmit/receive.
Pulser: -200V square wave pulser. Pulse width 100ns. Rise/fall times <10ns into 50 ohms:
P.R.F:1000 Hz.
Update Rate:60Hz (NTSC Mode); 50Hz (PAL Mode).
Rectification:Full wave.
Frequency:Range 2.5MHz and 5.0MHz.
Measurement: Modes:Mode 1: Signal Monitor
Mode 2: Depth and amplitude of first signal in gate.
Mode 3: Echo-to-Echo distance measurement. (single gate)
Mode 4: Trigonometric display of beam path, surface distance and depth of indication, curve surface correction and X-OFFSET for probe index. Half skip indication on screen.
Mode 5: T-Min mode for holding minimum thickness reading.
Resolution:0.01mm (0.001in) for distance measurement or 1% FSH for amplitude
measurement. Large display of measurement at the top of A-Scan display. Measurement mode selectable between peak and flank.
Thickness Logging:Storage for 8000 thickness readings configured either by Block/Location/Number mode or pre-programmable work sheets in sequential mode. Readings can be exported to MS Excel using optional SDMS software.
DAC:DAC defined by up to 10 points and digitally drawn on screen. DAC curves meet requirements of EN 1714, JIS and ASME standards, selectable between -2, -6, -10, -12 and -14dB. Amplitude read out selectable between % DAC or relative dB.
RS 125 Falcon -