Sercal NDT, non destructive testing, non destructive test equipment, NDT repair and calibration, railway services and supplies, ultrasonic flaw detectors, ultrasonic thickness meters, calibration blocks, probes krautkramer, probes sonatest, probes sonomatic, eddy current equipment, holiday detectors, mpi equipment and accessories, light meters,Sercal NDT, non destructive testing, non destructive test equipment, NDT repair and calibration, railway services and supplies, ultrasonic flaw detectors, ultrasonic thickness meters, calibration blocks, probes krautkramer, probes sonatest, probes sonomatic, eddy current equipment, holiday detectors, mpi equipment and accessories, light meters,
 

Sercal NDT, non destructive testing, non destructive test equipment, NDT repair and calibration, railway services and supplies, ultrasonic flaw detectors, ultrasonic thickness meters, calibration blocks, probes krautkramer, probes sonatest, probes sonomatic, eddy current equipment, holiday detectors, mpi equipment and accessories, light meters,

 
 
CALIBRATION BLOCKS - page 1

Order Code

Type
DESCRIPTION

.

 

No.1 (V1)

European standard
(A2) (BS EN12223).
No1 Calibration block - 25mm thick
Complete with fabric case & traceable certification.

No.1
European standard
(A2) (BS EN12223).
No1 Calibration block - 50mm thick
Complete with fabric case & traceable certification.
No.1
No1 Wooden carry case

No.1

No1 Calibration Standard:
Calibration of shear and compression wave probes. Checking beam angle, emergent point and resolution. Calibration of time base and gain settings.
(V1 specification also available) (Generally as above).
Calibration Block - Sercal
Formerly known as V1, but now manufactured to EN 12223. Major differences: no perspex insert and the through drilled hole is now 3mm instead of 1.5mm.

No.2 (V2)

European standard
(A4) (BS EN27963).
No2 Calibration block - 12.5mm thick

No.2 (V2)
European standard
(A4) (BS EN27963).
No2 Calibration block - 20mm thick

 

  Both items complete with leather wallet & traceable certification.

 

No.2
(V2)

EN12223 Dec.1999
(BS2704) DIN54120
Tolerance +/- 0.1mm
No2 Calibration Standard:
Small calibration block for site checking of shearwave probes, time base and gain settings. 5mm diameter hole target.
(V2 specification also available)
(Generally as above) (1.5mm or 5mm target hole).
Calibration Block - Sercal
Formerly known as V2, but now manufactured to EN 27963. Major difference: The target hole is now 5mm only.

BCB (IOW)

A5
BCB A5 Calibration block
Complete with fabric case & traceable certification.

BCB

(BS2704)

Tolerance +/- 0.1mm
Beam Calibration Block:
Beam profile and resolution checks for shear wave probes. Sensitivity checks for shear and compression probes. 9off 1.5mm holes.

Calibration Block - Sercal


A6

A6 (BS 2704)
A6 Calibration block
Complete with traceable certification.

A6
Wooden carry case

A6

(BS2704)

Tolerance +/- 0.1mm
Evaluating dominant frequency, pulse length, dead zone and resolving power for shear and compression probes as BS4331 part3, 1974 (1987).

Calibration Block - Sercal


RTB

A7 (BS 2704)
RTB (A7) Calibration block

 
 
Wooden carry case

RTB

(BS2704)

Tolerance +/- 0.1mm
Checking shear wave probe resolution as BS4331 part 3, 1974 (1984). Steps 2, 3, 4 and 5mm.

Calibration Block - Sercal


MU

Special
MU Calibration block
Complete with fabric case & traceable certification.

MU

(BS2704)

Tolerance +/- 0.1mm
Meric Universal Block:
for general purpose checking as No1 block.

Calibration Block - Sercal


TBR2 125

Special
TBR2 125 with 3 x 1.5mm holes
Complete with traceable certification.

 
TBR2 125
Special
TBR2 125 with 5 x 1.5mm holes
Complete with traceable certification.

TBR2
125

(BS2704)

Tolerance +/- 0.1mm
Radiused Test Block:
for calibration of boiler probes.
Available with 3 or 5 x 1.5mm diameter holes.

Calibration Block - Sercal


 